Comptes Rendus
The next generation radiotelescopes / Les radiotélescopes du futur
High dynamic-range radio-interferometric images at 327 MHz
Comptes Rendus. Physique, Volume 13 (2012) no. 1, pp. 14-22.

Radio astronomical imaging using aperture synthesis telescopes requires deconvolution of the point spread function as well as calibration of the instrumental characteristics (primary beam) and foreground (ionospheric/atmospheric) effects. These effects vary in time and also across the field of view, resulting in directionally-dependent (DD), time-varying gains. The primary beam will deviate from the theoretical estimate in real cases at levels that will limit the dynamic range of images if left uncorrected. Ionospheric electron density variations cause time and position variable refraction of sources. At low frequencies and sufficiently high dynamic range this will also defocus the images producing error patterns that vary with position and also with frequency due to the chromatic aberration of synthesis telescopes. Superposition of such residual sidelobes can lead to spurious spectral signals. Field-based ionospheric calibration as well as “peeling” calibration of strong sources leads to images with higher dynamic range and lower spurious signals but will be limited by sensitivity on the necessary short-time scales. The results are improved images although some artifacts remain.

La formation des images radio-astronomiques obtenues avec un réseau de télescopes de synthèse nécessite la déconvolution de la fonction de réponse à une source ponctuelle ainsi que lʼétalonnage des caractéristiques instrumentales (faisceau primaire) et des effets de propagation (ionosphère/atmosphère). Ces effets varient avec la position et aussi avec le temps. Le faisceau primaire réel va dévier de lʼestimation théorique à des niveaux qui vont limiter la dynamique des images à moins quʼon ne les corrige. Les variations de densité dʼélectrons ionosphériques vont provoquer une réfraction variable dépendant de la position des sources et du temps. Aux basses fréquences et à suffisamment haute dynamique les images seront défocalisées de façon variable dépendant de la position et aussi de la fréquence, à cause de lʼaberration chromatique des télescopes de synthèse. La superposition des lobes résiduels peut alors générer de faux signaux spectraux. Lʼétalonnage de la réfraction ionosphérique en fonction de la position et du temps ainsi que lʼautocalibration sur les sources les plus puissantes ( « peeling ») permettent dʼaugmenter la dynamique des images et de diminuer les signaux parasites, mais ils sont limités par la sensibilité disponible aux courts temps de pose. On obtient ainsi des images améliorées, bien que certains artefacts demeurent.

Published online:
DOI: 10.1016/j.crhy.2011.10.016
Keywords: Image processing techniques, Interferometric techniques, Data analysis methods
Mot clés : Traitement des images, Interférométrie techniques, Méthodes dʼanalyse des données

Juan M. Uson 1; William D. Cotton 2

1 Observatoire de Paris – LERMA, 61 avenue de lʼObservatoire, 75014 Paris, France
2 NRAO, 520 Edgemont Road, Charlottesville, VA 22903, USA
@article{CRPHYS_2012__13_1_14_0,
     author = {Juan M. Uson and William D. Cotton},
     title = {High dynamic-range radio-interferometric images at 327 {MHz}},
     journal = {Comptes Rendus. Physique},
     pages = {14--22},
     publisher = {Elsevier},
     volume = {13},
     number = {1},
     year = {2012},
     doi = {10.1016/j.crhy.2011.10.016},
     language = {en},
}
TY  - JOUR
AU  - Juan M. Uson
AU  - William D. Cotton
TI  - High dynamic-range radio-interferometric images at 327 MHz
JO  - Comptes Rendus. Physique
PY  - 2012
SP  - 14
EP  - 22
VL  - 13
IS  - 1
PB  - Elsevier
DO  - 10.1016/j.crhy.2011.10.016
LA  - en
ID  - CRPHYS_2012__13_1_14_0
ER  - 
%0 Journal Article
%A Juan M. Uson
%A William D. Cotton
%T High dynamic-range radio-interferometric images at 327 MHz
%J Comptes Rendus. Physique
%D 2012
%P 14-22
%V 13
%N 1
%I Elsevier
%R 10.1016/j.crhy.2011.10.016
%G en
%F CRPHYS_2012__13_1_14_0
Juan M. Uson; William D. Cotton. High dynamic-range radio-interferometric images at 327 MHz. Comptes Rendus. Physique, Volume 13 (2012) no. 1, pp. 14-22. doi : 10.1016/j.crhy.2011.10.016. https://comptes-rendus.academie-sciences.fr/physique/articles/10.1016/j.crhy.2011.10.016/

[1] A.R. Thompson; J.M. Moran; G.W. Swenson Interferometry and Synthesis in Radio Astronomy, Wiley, 2001

[2] J.P. Hamaker; J.D. Bregman; R.J. Sault Astron. Astrophys. Suppl. Ser., 117 (1996), p. 137

[3] J.M. Uson; W.D. Cotton Astron. Astrophys., 486 (2008), p. 647

[4] W.D. Cotton Synthesis Imaging Radio Astronomy (R.A. Perley; F.R. Schwab; A.H. Bridle, eds.), ASP Conf. Ser., vol. 6, ASP, San Francisco, 1989, p. 243

[5] F.R. Schwab Indirect Imaging, Measurement and Processing for Indirect Imaging (J.A. Roberts, ed.), Cambridge University Press, Cambridge, England–New York, 1983, p. 333

[6] W.D. Cotton Multi-facet CLEANing in obit, 2009 ftp://ftp.cv.nrao.edu/NRAO-staff/bcotton/Obit/MultiClean.pdf (Obit Development Memo Series No. 15)

[7] W.D. Cotton Publ. Astron. Soc. Pacific, 120 (2008), p. 439

[8] W.D. Cotton Lessons from the VLA Long Wavelength Sky Survey (VLSS), Astron. Soc. Pac. Conf. Ser., Volume 345 (2005), pp. 337-340

[9] W.D. Cotton; J.J. Condon; R.A. Perley et al. Beyond the isoplanatic patch in the VLA low-frequency sky survey, Proc. SPIE, Volume 5489 (2004), pp. 180-189

[10] T.J. Cornwell; J.M. Uson; N. Haddad Astron. Astrophys., 258 (1992), p. 583

[11] J. M. Uson, D. S. Bagri, VLA Primary Beam and Pointing at 333 MHz, VLA Test Memo #157, 1991.

[12] J.M. Uson; D.S. Bagri; T.J. Cornwell Astrophys. J. Lett., 377 (1991), p. L65

[13] J.J. Condon; W.D. Cotton; E.W. Greisen et al. Astrophys. J., 115 (1998), p. 1693

[14] W.D. Cotton; J.M. Uson Astron. Astrophys., 490 (2008), p. 455

[15] T.J. Cornwell; R.A. Perley Astron. Astrophys., 261 (1992), p. 353

[16] J.E. Noordam, Peeling the visibility onion, the optimum way of self-calibration, ASTRON Tech. report MEM-078, 2003.

Cited by Sources:

Comments - Policy