This article introduces a measurement methodology for the evaluation of the specific absorption rate (SAR) of MIMO systems (multiple-input and multiple-output) in which the relative phases between the antennas are rapidly changing and in very short durations.
This measurement methodology is enabled by SAR systems that uses vector field measurements combined with a vector spectral analysis of the measured radiofrequency signals for SAR assessment. By exploiting the equivalence principle and the uniqueness of the solution of Maxwell’s equation, the proposed approach allows for an accurate SAR assessment of complex MIMO systems in a very short duration (few seconds).
Publié le :
Mounir Teniou 1 ; Mehdi Ramdani 1 ; Ourouk Jawad 1 ; Thomas Julien 1 ; Stéphane Pannetrat 1 ; Lyazid Aberbour 1
@article{CRPHYS_2021__22_S1_25_0, author = {Mounir Teniou and Mehdi Ramdani and Ourouk Jawad and Thomas Julien and St\'ephane Pannetrat and Lyazid Aberbour}, title = {On the measurement procedures for the assessment of the specific absorption rate {(SAR)} from {MIMO} cellular-equipment of fast varying relative phases}, journal = {Comptes Rendus. Physique}, pages = {25--33}, publisher = {Acad\'emie des sciences, Paris}, volume = {22}, number = {S1}, year = {2021}, doi = {10.5802/crphys.64}, language = {en}, }
TY - JOUR AU - Mounir Teniou AU - Mehdi Ramdani AU - Ourouk Jawad AU - Thomas Julien AU - Stéphane Pannetrat AU - Lyazid Aberbour TI - On the measurement procedures for the assessment of the specific absorption rate (SAR) from MIMO cellular-equipment of fast varying relative phases JO - Comptes Rendus. Physique PY - 2021 SP - 25 EP - 33 VL - 22 IS - S1 PB - Académie des sciences, Paris DO - 10.5802/crphys.64 LA - en ID - CRPHYS_2021__22_S1_25_0 ER -
%0 Journal Article %A Mounir Teniou %A Mehdi Ramdani %A Ourouk Jawad %A Thomas Julien %A Stéphane Pannetrat %A Lyazid Aberbour %T On the measurement procedures for the assessment of the specific absorption rate (SAR) from MIMO cellular-equipment of fast varying relative phases %J Comptes Rendus. Physique %D 2021 %P 25-33 %V 22 %N S1 %I Académie des sciences, Paris %R 10.5802/crphys.64 %G en %F CRPHYS_2021__22_S1_25_0
Mounir Teniou; Mehdi Ramdani; Ourouk Jawad; Thomas Julien; Stéphane Pannetrat; Lyazid Aberbour. On the measurement procedures for the assessment of the specific absorption rate (SAR) from MIMO cellular-equipment of fast varying relative phases. Comptes Rendus. Physique, Volume 22 (2021) no. S1, pp. 25-33. doi : 10.5802/crphys.64. https://comptes-rendus.academie-sciences.fr/physique/articles/10.5802/crphys.64/
[1] Antennas in cellular phones for mobile communications, Proc. IEEE, Volume 100 (2012) no. 7, pp. 2286-2296 | DOI
[2] Guidelines for limiting exposure to electromagnetic fields (100 kHz to 300 GHz), Health Phys., Volume 118 (2020) no. 5, pp. 483-524
[3] Guidance for evaluating exposure from multiple electromagnetic sources (2010) no. 62630 (https://webstore.iec.ch/publication/7288) (Technical report)
[4] Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices—Part 3: Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz) (2019) no. 62209-3 (https://webstore.iec.ch/publication/30773) (Technical report)
[5] et al. Exposure compliance methodologies for multiple input multiple output (MIMO) enabled networks and terminals, IEEE Trans. Antennas Propag., Volume 60 (2011) no. 2, pp. 644-653 | DOI
[6] et al. A fast estimation technique for evaluating the specific absorption rate of multiple-antenna transmitting devices, IEEE Trans. Antennas Propag., Volume 65 (2017) no. 4, pp. 1947-1957 | MR
[7] et al. Averaging time required for measuring the specific absorption rate of a MIMO transmitter, IEEE Electromagn. Compat. Mag., Volume 3 (2014) no. 1, pp. 57-64
[8] et al. A novel technology for fast and accurate specific absorption rate measurement, 2013 International Workshop on Antenna Technology (iWAT) (2013), pp. 363-366 | DOI
[9] et al. Efficient experimental assessment of the specific absorption rate (SAR) induced by MIMO wireless communication devices; application of vector near-field measurement system, 2018 IEEE Conference on Antenna Measurements & Applications (CAMA) (2018), pp. 1-4
[10] et al. A fast and rigorous assessment of the specific absorption rate (SAR) for MIMO cellular equipment based on vector near-field measurements, 2020 14th European Conference on Antennas and Propagation (EuCAP) (2020), pp. 1-5
[11] https://www.empire.de/)