Comptes Rendus
On perspective errors in endoscopic PIV
Comptes Rendus. Mécanique, Volume 332 (2004) no. 9, pp. 687-692.

Results are presented from a single and dual lens endoscopic PIV imaging system with a view to application of PIV where optical access is restricted such as internal flows. The dual lens PIV images were processed using cross-correlation, a cubic mapping function and standard stereoscopic relationships. For the single lens system, the images were processed using cross-correlation and a quadratic distortion-mapping function. Results have shown the single lens system to have in-plane errors an order of magnitude greater than the stereoscopic dual lens endoscopic PIV system. These errors are generated by perspective effects. Use of the stereo arrangement is therefore recommended wherever quantitative 3D velocimetry data is acquired using an endoscopic system.

On présente les résultats nouveaux obtenus à l'aide d'un système d'imagerie PIV endoscopique, à lentille simple ou double , en vue d'application à la PIV (Vélocimétrie Particulaire par Imagerie ) dans les situations avec accès optique direct difficile, comme dans des écoulements internes. Les images PIV à lentille duale ont été traitées en utilisant la corrélation croisée, une fonction de correspondance cubique et les relations stéréoscopiques standard. Dans le cas de du système à lentille unique, les images ont été traitées en utilisant la corrélation croisée avec fonction de distorsion quadratique. Les résultats démontrent que dans le cas d'une lentille unique, les erreurs dans le plan de vision sont d'un ordre de grandeur supérieure aux celles du système PIV endoscopique à double lentille. Ces erreurs sont engendrées par effets de perspective. De ce fait, il est recommandé d'employer la technique stéréoscopique chaque fois où les données quantitatives vélocimétriques sont obtenus avec l'utilisation d'un système endoscopique.

Received:
Accepted:
Published online:
DOI: 10.1016/j.crme.2004.04.002
Keywords: Signal processing, Stereoscopic PIV, Endoscope, Perspective errors
Mots-clés : Traitement du signal, PIV stéréoscopique, Endoscope, Erreurs de perspective

Mark Reeves 1; Nicholas John Lawson 2

1 Lothian Imaging Sciences Ltd, 3/2 Boroughlough Lane, Edinburgh EH8 8NL, UK
2 Department of Aerospace Sciences, College of Aeronautics, Cranfield University, Cranfield, Beds MK43 OAL, UK
@article{CRMECA_2004__332_9_687_0,
     author = {Mark Reeves and Nicholas John Lawson},
     title = {On perspective errors in endoscopic {PIV}},
     journal = {Comptes Rendus. M\'ecanique},
     pages = {687--692},
     publisher = {Elsevier},
     volume = {332},
     number = {9},
     year = {2004},
     doi = {10.1016/j.crme.2004.04.002},
     language = {en},
}
TY  - JOUR
AU  - Mark Reeves
AU  - Nicholas John Lawson
TI  - On perspective errors in endoscopic PIV
JO  - Comptes Rendus. Mécanique
PY  - 2004
SP  - 687
EP  - 692
VL  - 332
IS  - 9
PB  - Elsevier
DO  - 10.1016/j.crme.2004.04.002
LA  - en
ID  - CRMECA_2004__332_9_687_0
ER  - 
%0 Journal Article
%A Mark Reeves
%A Nicholas John Lawson
%T On perspective errors in endoscopic PIV
%J Comptes Rendus. Mécanique
%D 2004
%P 687-692
%V 332
%N 9
%I Elsevier
%R 10.1016/j.crme.2004.04.002
%G en
%F CRMECA_2004__332_9_687_0
Mark Reeves; Nicholas John Lawson. On perspective errors in endoscopic PIV. Comptes Rendus. Mécanique, Volume 332 (2004) no. 9, pp. 687-692. doi : 10.1016/j.crme.2004.04.002. https://comptes-rendus.academie-sciences.fr/mecanique/articles/10.1016/j.crme.2004.04.002/

[1] R.J. Adrian Particle-imaging techniques for experimental fluid mechanics, Annu. Rev. Fluid Mech., Volume 23 (1991), pp. 261-304

[2] A.K. Prasad Stereoscopic particle image velocimetry, Exp. Fluids, Volume 29 (2000) no. 2, pp. 103-116

[3] N.J. Lawson; J. Wu Three-dimensional particle image velocimetry: error analysis of stereoscopic techniques, Meas. Sci. Technol., Volume 8 (1997), pp. 894-900

[4] C. Willert Stereoscopic digital particle image velocimetry for application in wind tunnel flows, Meas. Sci. Technol., Volume 8 (1997), pp. 1465-1479

[5] D.P. Hand; J.D. Entwistle; R.R.J. Maier; A. Kuhn; C.A. Greated; J.D.C. Jones Fibre optic beam delivery system for high peak power laser PIV illumination, Meas. Sci. Technol., Volume 10 (1999), pp. 239-245

[6] U. Dierksheide; P. Meyer; T. Hovestadt; W. Hentschel Endoscopic 2D-PIV flow field measurements in IC engines, 4th International Symposium on Particle Image Velocimetry Göttingen, Germany, September 17–19, 2001, PIV'01, 2001 (Paper 1060)

[7] T. Geis; G. Rottenkolber; M. Dittmann; B. Richter; K. Dullenkopf; S. Wittig Endoscopic PIV-measurements in a enclosed rotor–stator system with pre-swirled cooling air, Proc. of the 11th Int. Symp. on Apps. of Laser Tech. to Fluid Mech., July 8th–11th, Lisbon, Portugal, 2002 (Paper 26.4)

[8] S.M. Sollof; R.J. Adrian; Z.-C. Liu Distortion compensation for generalised stereoscopic particle image velocimetry, Meas. Sci. Technol., Volume 8 (1997), pp. 1441-1454

Cited by Sources:

Comments - Policy