Comptes Rendus
A tool for controlling accelerometers. Secondary calibration data
Comptes Rendus. Mécanique, Volume 341 (2013) no. 9-10, pp. 687-696.

Vibration monitoring requires acceleration transducers capable of providing data with high precision. Accelerometers are the most frequently used vibration transducers. Their calibration plays an important role in measuring vibrations and is a key component in ensuring the integrity of the vibration measurement. For managing secondary calibration data of accelerometers, a database computer system was implemented. The implementation of this software has been an important step forward in providing a wide range of analysis and display tools. This paper reviews the main concepts involving accelerometer secondary calibration and describes the tool developed and the methods used in its development.

Reçu le :
Accepté le :
Publié le :
DOI : 10.1016/j.crme.2013.09.007
Mots clés : Accelerometer, Secondary calibration, Vibration testing, Database
Fernando Juliani 1 ; Everaldo de Barros 1 ; Mauro Hugo Mathias 2

1 Institute of Aeronautics and Space, Integration and Tests Division, Praça Marechal Eduardo Gomes, 50, 12228-904, São José dos Campos, SP, Brazil
2 Universidade Estadual Paulista “Júlio de Mesquita Filho”, Campus de Guaratinguetá, Avenida Doutor Ariberto Pereira da Cunha, 333, 12516-410, Guaratinguetá, SP, Brazil
@article{CRMECA_2013__341_9-10_687_0,
     author = {Fernando Juliani and Everaldo de Barros and Mauro Hugo Mathias},
     title = {A tool for controlling accelerometers. {Secondary} calibration data},
     journal = {Comptes Rendus. M\'ecanique},
     pages = {687--696},
     publisher = {Elsevier},
     volume = {341},
     number = {9-10},
     year = {2013},
     doi = {10.1016/j.crme.2013.09.007},
     language = {en},
}
TY  - JOUR
AU  - Fernando Juliani
AU  - Everaldo de Barros
AU  - Mauro Hugo Mathias
TI  - A tool for controlling accelerometers. Secondary calibration data
JO  - Comptes Rendus. Mécanique
PY  - 2013
SP  - 687
EP  - 696
VL  - 341
IS  - 9-10
PB  - Elsevier
DO  - 10.1016/j.crme.2013.09.007
LA  - en
ID  - CRMECA_2013__341_9-10_687_0
ER  - 
%0 Journal Article
%A Fernando Juliani
%A Everaldo de Barros
%A Mauro Hugo Mathias
%T A tool for controlling accelerometers. Secondary calibration data
%J Comptes Rendus. Mécanique
%D 2013
%P 687-696
%V 341
%N 9-10
%I Elsevier
%R 10.1016/j.crme.2013.09.007
%G en
%F CRMECA_2013__341_9-10_687_0
Fernando Juliani; Everaldo de Barros; Mauro Hugo Mathias. A tool for controlling accelerometers. Secondary calibration data. Comptes Rendus. Mécanique, Volume 341 (2013) no. 9-10, pp. 687-696. doi : 10.1016/j.crme.2013.09.007. https://comptes-rendus.academie-sciences.fr/mecanique/articles/10.1016/j.crme.2013.09.007/

[1] ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories, International Organization for Standardization, Switzerland, 2005

[2] M. Serridge; T.R. Licht Piezoelectric Accelerometer and Vibration Preamplifier Handbook, K. Larsen & Son A/ S, Glostrup, 1987

[3] G. Buzdugan; E. Mihailescu; M. Rades Vibration Measuring, Martinus Nijhoff Publishers, Bucharest, Romania, 1986

[4] K.G. McConnell; P.S. Varoto Vibration Testing: Theory and Practice, John Wiley & Sons, New York, USA, 2008

[5] ISO 16063-21:2003 Methods for the calibration of vibration and shock transducers – Part 21: Vibration calibration by comparison to a reference transducer, International Organization for Standardization, Switzerland, 2003

[6] T. Critchlow Data foundry: information management for scientific data, IEEE Trans. Inf. Technol. Biomed., Volume 4 (2000), pp. 52-57

[7] J.Z. Sikorska; P.J. Kelly; J. Pan Development of an AE data management and analysis system, Mech. Syst. Signal Process., Volume 20 (2005) no. 8, pp. 2321-2339

[8] C.J. Carleton; R.A. Dahlgren; K.W. Tate A relational database for the monitoring and analysis of watershed hydrologic functions: II. Data manipulation and retrieval programs, Comput. Geosci., Volume 31 (2005) no. 4, pp. 403-413

[9] H. Kjeldsen; J. Olsen; J. Heinemeier An integrated data-analysis and database system form AMS 14C, Nucl. Instrum. Methods Phys. Res. B, Volume 268 (2010) no. 7–8, pp. 980-984

[10] V. Batagelj; J. Bojkovski; J. Drnovsek Software integration in national measurement-standards laboratories, Sci. Meas. Technol., Volume 2 (2008), pp. 100-106

[11] I. Sommerville Software Engineering, Pearson Addison-Wesley, Boston, MA, USA, 2007

[12] C.J. Date An Introducting to Database Systems, Pearson Addison-Wesley, Boston, MA, USA, 2003

[13] D. Petkovic SQL Server 2000 – A Beginnerʼs Guide, Osborne McGraw-Hill, Berkeley, CA, USA, 2000

[14] S. Teixeira; X. Pacheco Delphi 6 Developerʼs Guide, Sams Publishing, USA, 2002

Cité par Sources :

Commentaires - Politique


Ces articles pourraient vous intéresser

Autonomous system for data collection: Location and mapping issues in post-disaster environment

Tullio Joseph Tanzi; Jean Isnard

C. R. Phys (2019)


The Corinth Gulf Soft Soil Array (CORSSA) to study site effects

Kyriazis Pitilakis; Konstantinos Makropoulos; Pascal Bernard; ...

C. R. Géos (2004)


The MICROSCOPE space mission to test the Equivalence Principle

Pierre Touboul; Gilles Métris; Manuel Rodrigues; ...

C. R. Phys (2020)