1. Introduction
Heavy metal ions severely pollute water due to their high toxicity and non-biodegradability [1]. These heavy metal ions can diffuse into the food chain of animals and eventually into human food, which can pose serious risks to human health [2]. Cadmium and lead are two very common toxic metal ions capable of inducing severe human diseases and health problems [3]. According to the World Health Organization, standards on permissible limits of cadmium and lead in water are 0.01 and 0.05 mg⋅L−1, respectively [4]. For drinking water, standards on permissible limits of cadmium and lead are 3 and 10 μg⋅L−1, respectively [5]. Levels above these limits can result in skin, kidney, lung, bladder, and liver cancers as well as cardiovascular and infectious diseases, tissue injury, and anemia [6, 7]. Several techniques have been developed for the analytical determination of Cd2+ and Pb2+ ions among which inductively coupled plasma–optical emission spectroscopy [8], inductively coupled plasma–mass spectrometry [9], and graphite furnace atomic absorption spectrometry [10] are worth mentioning. These methods, however, require expensive equipment and trained operators. In this work, an atomic absorption spectrometer equipped with a flame atomizer was used to determine the concentration of both metal ions. This technique allows the determination of many elements with high sensitivity with efficient background correction [11].
Lichen is a composite organism produced by algae or cyanobacteria living among filaments of multiple fungi species in a mutualistic relationship [12]. Some lichens are used as medicines or food in some regions [13]. They can also serve as bio-indicators of air pollutants [14]. Recently, green nanotechnology methods have been applied to the synthesis of nanoparticles (NPs) through other simple techniques [15]. The green synthesis of NPs from natural biological resources such as lichens is an inexpensive, efficient, eco-friendly, chemical-free, and sustainable method [16]. In the past few years, some types of lichens [17], algae [18], fungi [19], and bactericidal agents [20] have been utilized to synthesize non-toxic and useful metallic NPs. In this study, the synthesis of iron oxide NPs by the plant extract of lichen Ramalina sinensis (RS) was explored.
Among the different types of NPs, Fe3O4 NPs have exhibited various advantages in the fields of nanobiotechnology and wastewater treatment [21]. Iron oxide NPs have been gaining the attention of the research community in solving environment-related problems [22]. This is because they have a high surface-area-to-volume ratio; so their surface can be used as an excellent adsorbent to remove dyes and toxic heavy metals from aqueous solutions [23]. On the other hand, nanocomposites have been increasingly studied to be used as nanofiltration membranes for water and wastewater treatment [24, 25, 26]. Pawar et al. found that the adsorption capacity of iron oxide modified clay-activated carbon composite beads for the removal of hazardous lead, arsenic, and cadmium from aqueous environments was high [27]. Horst et al. reported high sorption capacity of magnetic nanocomposites for the removal of Cu, Zn, Cd, and Cr as heavy metals [28]. The Nayak group reported a novel modified polyvinyl chloride (PVC) blend membrane with good efficiency for the removal of heavy metal ions, namely lead, cadmium, and chromium [29]. Recently, the Farjami group fabricated a new emulsion PVC microporous nanocomposite ultrafiltration membrane [30]. The removal of heavy metals and toxic dyes from wastewater has been studied by some researchers using other new polymer-based nanocomposites [31, 32, 33]. Following the valuable studies of these researchers, this work is aimed at the fabrication of a PVC/iron oxide nanocomposite membrane (NCM) and its application in the removal of cadmium and lead ions from an aqueous solution.
Among the various polymeric materials used in the fabrication of nanofiltration membranes, PVC has exhibited higher durability and flexibility [34]. In this work, PVC and sodium dodecyl sulfate (SDS, as an anionic surfactant) were used to form a new NCM containing iron oxide NPs for the removal of Cd2+ and Pb2+ from aqueous solutions. Sodium dodecyl sulfate is also one of the most applicable surfactants in the fabrication of nanofiltration membranes due to its high hydrophilicity and biocompatibility as well as cost-effectiveness compared with other more complex surfactants [35]. Polymer–metal NCMs are considered as a new class of adsorbents with interesting chemical and physical properties since they possess all the essential features [36]. Water treatment technologies including membrane separation [37], chemical coagulation [38] and precipitation [39], ion exchange [40], and electrochemical treatment [41] have been employed for the removal of heavy metal ions from aqueous solutions. However, among these techniques, adsorption processes are inexpensive, fast, and efficient, which enables their application to the removal of toxic metal ions [42, 43, 44, 45].
2. Materials and methods
2.1. Materials
PVC (MW: 78,000 g/mol; Arvand Petrochemical Company, Iran) and SSD (MW: 288.38 g/mol; Merck, Germany) were employed as the polymer and the surfactant for the fabrication of NCM films, respectively (their structures are shown in Figure 1). Tetrahydrofuran (THF, d: 889 kg∕m3; Sigma-Aldrich, Germany) and dimethylacetamide (DMA, d: 940 kg∕m3; Sigma-Aldrich, Germany) were used as the solvents. FeCl2⋅4H2O (99%; Merck, Germany), FeCl3⋅6H2O (99%; Sigma-Aldrich, Germany), NH3 (28%; Merck, Germany), and native lichen RS (collected from the Fandoqlu Forest in the southeastern region of Ardabil, Iran) were used for the synthesis of iron oxide NPs. NaOH (96%; Tianjin Yongda Chemical Reagent Company, China) and HCl (36%; Chongqing Dongchuan Chemical Company, China) were also utilized to adjust the pH of the solutions. Cadmium nitrate tetrahydrate and lead(II) nitrate (Merck, Germany) were used to prepare the required stock solution.
2.2. Equipment
The UV–visible spectrum of the NPs was obtained using a UV-2450 Shimadzu spectrophotometer. Fourier-transform infrared (FTIR) spectra of the PVC, iron oxide NPs, and PVC/iron oxide NCM were recorded by an FTIR Bruker spectrometer. X-ray diffraction (XRD) patterns of the synthesized iron oxide NPs and NCM were obtained by a Philips PW1730 diffractometer operating with Cu K𝛼 radiation (𝜆= 0.154 nm). The surface morphology of the NPs and PVC/iron oxide NCM was observed through a field emission scanning electron microscope (FESEM, TESCAN MIRA III). Adsorption–desorption isotherms of nitrogen were evaluated by a high-precision surface area and pore size analyzer (BELSORP MINI II). A vibrating sample magnetometer (VSM) with MDKF-FORC/VSM (Meghnatis-Daghigh-Kashan Co.) was also employed to study the magnetic properties of the samples. The residual concentration of Cd2+ and Pb2+ ions after the adsorption process was evaluated by a flame atomic absorption spectrophotometer (FAAS, PerkinElmer AAnalyst 300). Differential thermal gravimetric analysis (TGA/DTG) was performed by a Linseis STA PT1000 instrument.
2.3. Synthesis of iron oxide NPs
Iron oxide NPs were synthesized by the co-precipitation method as reported in previous work [46]. First, 10 mL of the extract obtained from the distillation of 10 g lichen RS was added to a 100 mL solution of Fe3+/Fe2+ at a ratio of 2:1 in a 250 mL volumetric flask. The prepared solution was vigorously stirred using a magnetic stirrer at 70 °C for 1 h. During this time, 1 mL of ammonia solution (0.1 M) was added dropwise to the flask to complete the NP synthesis reaction. After decantation and filtration, the brownish NPs obtained were rapidly washed with double distilled water until the solution pH reached the neutral range near 7. The synthesized NPs were then washed with ethanol and dried in an oven at 50 °C for 24 h. They were then calcined at the range of 500 −−700 °C for 3 h in a muffle furnace. This black product was stored in a desiccator for later use.
2.4. Fabrication of polymer-based NCM
For this purpose, 85.7 mL of THF and 14.3 mL of DMA were mixed in a laboratory glass under the hood. Then, 12 g of PVC and 0.45 g of SDS were added in a conical flask; a sufficient amount of solvent mixture (85:15 wt%) was added to prepare 100 g of the mixture. The prepared mixture was vigorously stirred using a magnetic stirrer for 20 min at 25 °C, and it was then placed inside an ultrasonic device for 15 min to obtain a perfectly homogeneous mixture. To prepare NCMs containing 0.5 wt% iron oxide NPs, the same steps were followed, but 0.5 g iron oxide NPs were added in the flask before the mixture weight was increased to 100 g. Subsequently, the obtained mixtures were cast on a clean glass plate with dimensions of 20 × 15 cm2 at ambient temperature by a manual casting knife with 300 μm thickness. The membrane surface was exposed to airflow at 27 °C for 30 min to evaporate the excess solvent. Then, it was immersed in a distilled water bath at ambient temperature. The polymer-based NCM layer was taken out after 20 min and then immersed again in the distilled water bath for 24 h to ensure the complete removal of the remaining solvent. The cadmium and lead removal performance of the fabricated NCMs was assessed in aqueous solutions.
2.5. Adsorption experiments
First, a polyvinyl syringe with a capacity of 5 mL and an effective area of 1.13 cm2 was chosen and its plungers were removed. Then, the fabricated NCM film was cut to fit the inner diameter of the syringe (almost 12 mm) and inserted to its end. The solutions with the required concentrations of Cd(II) and Pb(II) were prepared by diluting a suitable stock solution. Different concentrations of cadmium and lead ion solutions were passed through the unused NCM film under constant pressure generated by an air cylinder, and the residual concentrations of the collected solutions were determined using an FAAS. The removal percentage (%R) of each ion was calculated by (1).
(1) |
(2) |
3. Results and discussion
3.1. Characterization of iron oxide NPs and fabricated NCM
The UV–visible absorption spectrum of the synthesized iron oxide NPs was compared with the spectrum of the Fe2+/Fe3+ solution and the pristine RS extract shown in Figure 2. The broad absorption peak in Figure 2a corresponds to iron oxide NPs showing strong absorption at a wavelength of ∼350 nm. This can be attributed to direct electron transition corresponding to the optical bandgap energy in the range of 1.92–2.87 eV [47, 48]. The maximum surface plasmon resonance band of iron oxide NPs occurs at a wavelength of ∼250 nm, indicating a reduction of ferric ions to iron oxide by the carbonyl of the aldehyde group existing in the RS extract [49].
The crystal structure of the products was characterized by a Philips PW1730 diffractometer. The XRD patterns of products with Cu K𝛼 radiation (𝜆= 0.154 nm) were recorded in the 2𝜃 range of 10°–80° (see Figure 3). Six characteristic peaks at 30.40° (29.88°), 35.75° (35.33°), 43.45° (42.98°), 53.80° (53.17°), 57.40° (56.92°), and 62.95° (62.61°) for iron oxide NPs (NCM) were obtained corresponding to the (220), (311), (400), (422), (511), and (440) crystal planes of pure Fe3O4 with a spinal structure, respectively. The XRD patterns of the prepared samples were compared with standard pattern JCPDS card no. 65-3107 [50], indicating good agreement between the obtained results and the standard values of magnetite NPs. Moreover, the diameter of NPs was evaluated ∼28 nm from the (311) plane with a diffraction peak at 2𝜃 = 35.75° using the Scherrer equation [51].
Figure 4 shows the FTIR spectrum of pristine PVC, Fe3O4 NPs, and fabricated NCM. According to Figure 4a, the sharp peaks at 611 and 689 cm−1 can be attributed to the C–Cl stretching vibrations in the PVC structure. In addition, the main peaks at 1097 and 2913 cm−1 are due to the C–C and C–H stretching vibrations in pure PVC, respectively. In the FTIR spectrum of Fe3O4 NPs (Figure 4b), the Fe–O–Fe bond stretching can be detected from the narrow peak at 569 cm−1. The presence of a broad band at approximately 3500 cm−1 and a weak band at 1640 cm−1 can be attributed to the stretching and bending vibrations of the adsorbed water molecules on the iron oxide NPs, respectively [36]. The FTIR spectrum of NCM (Figure 4c) presents the characteristic absorptions of pristine PVC and Fe3O4 NPs but with reduced intensity of the peaks associated with oxygen–iron bonding.
The morphology of the fabricated NCM containing 0.5 wt% Fe3O4 NPs was examined by a field emission scanning electron microscope equipped with an energy-dispersive X-Ray spectrometer (FESEM-EDS, TESCAN MIRA III). Figures 5a–f present the surface morphology of PVC and NCM at different magnification values. The particle size of iron oxide NPs in the structure of NCM is in the range of 25–70 nm, which can be ascribed to the agglomeration of iron oxide NPs during the formation of nanocomposites as a result of Van der Waals forces and magnetic interactions between the NPs [52]. Nevertheless, the unique shape and size distribution of NPs were not observed in the SEM images. There is no unidentified peak observed in the EDS spectrum (see Figure 6), suggesting the purity of the fabricated NCM. The peaks appearing in the EDS spectrum confirmed the presence of carbon, chlorine, oxygen, and iron elements with weight percentages of 43.25, 26.21, 24.72, and 5.82, respectively.
Figure 7 shows the adsorption–desorption isotherms of N2 onto the NCM at a saturated vapor pressure of 84.3 kPa and a temperature of 77 K. The shape of isotherms indicates the presence of both micro- and mesopores corresponding to isotherms of Type IV. The specific surface area, pore volume, and mean pore diameter of PVC and fabricated NCM are listed in Table 1. The mean pore diameter of NCM is 7.14 nm, which belongs to the mesoporous range (2–50 nm). However, it is near the microporous range (2 nm). The fabricated NCM in this work has a specific surface area of 5.670 m2⋅g−1, which is approximately thrice greater than the reported value for pure PVC.
BET experimental data deduced from N2 adsorption onto PVC and NCM containing 0.5 wt% iron oxide NPs
Samples | Specific surface area (m2⋅g−1) | Pore volume (mL⋅g−1) | Mean pore diameter (nm) | Ref. |
---|---|---|---|---|
PVC | 2.018 | 5.467 × 10−3 (average) | 26.74 | [53 ] |
NCM | 5.670 | 10.126 × 10−3 (total) | 7.14 | This work |
The magnetic properties of iron oxide NPs were measured by a VSM at a maximum applied field of 15000 Oe at ambient temperature. The magnetization plot of the fabricated NCM (Figure 8) shows no hysteresis loop and reveals a magnetic saturation of 6.11 emu⋅g−1 at room temperature. This is a significant decrease compared to the magnetic saturation of iron oxide NPs, which was reported elsewhere [54].
The TGA technique was used to determine the thermal stability of the fabricated NCM. The fraction of volatile components present in the NCM can also be determined by monitoring the weight change, which occurs as the sample is heated. The changes in the mass of PVC-based NCM as a function of temperature from 30 to 700 °C at a heating rate of 10 °C⋅min−1 were measured by TGA/DTG curves in N2 atmosphere. Figure 9 shows the TGA/DTG curves of the PVC-based NCM. The slight weight loss below ∼130 °C for NCM can be attributed to the evaporation of trapped THF and other volatile components. The curves in Figure 9 indicate that the fabricated NCM is remarkably stable up to 230 °C. A two-stage significant weight loss occurs in the degradation process. The first major weight loss is observed in the range of 133 −−333 °C, which corresponds to the loss of HCl [53]. The second major weight loss is observed in the range of 333 −−463 °C, which is much shorter than the first stage. Thermal degradation of the polymer backbone takes place at this stage, resulting in the formation of stable carbonaceous residue [55].
3.2. Adsorption isotherms
The influence of initial pH and concentration of diluted solutions on the removal percentage of Cd2+ and Pb2+ ions was investigated for various ranges at a constant dose of fabricated NCM and temperature. By considering the fact that Cd(II) and Pb(II) can generally be precipitated as hydroxides at pH values of 8.0 and 9.0, respectively, the adsorption studies were conducted in the pH range of 2.0–7.0 for Cd(II) and 2.0–8.0 for Pb(II) [56]. The pH of the solutions was adjusted by adding 0.01 M HCl or 0.01 M NaOH and measured using an electronic pH meter. The optimum conditions for the removal of ions were pH = 6 for Cd(II) and 8 for Pb(II), initial metal ionconcentration = 10 mg⋅L−1, nanocompositedose = 150 mg∕50 mL, contacttime = 1 h, and temperature = 25 ± 1 °C. For the adsorption experiments, a 50 mL solution of each ion of the required concentration (5 −−50 mg⋅L−1) at an optimum initial pH and nanocomposite dose was evaluated for 1 h.
The experimental data were evaluated by Langmuir and Freundlich isotherm models. The Langmuir adsorption model assumes that an adsorbent has a fixed number of binding sites. All the binding sites show the same affinity for the adsorbent. Therefore, each site adsorbs only one molecule and forms a single monolayer [57].
The linear form of the Langmuir model can be written as
(3) |
The linear form of the Freundlich model is given as
(4) |
Isotherm parameters and correlation coefficients (R2) for the adsorption of cadmium and lead ions onto the fabricated NCM at 298 K
Ions | Langmuir | Freundlich | |||||
---|---|---|---|---|---|---|---|
qm (mg⋅g−1) | b (L⋅mg−1) | R2 | RL | kF | n | R2 | |
Cd2+ | 11.55 | 0.34 | 0.999 | 0.06–0.37 | 2.74 | 1.95 | 0.960 |
Pb2+ | 11.40 | 0.52 | 0.999 | 0.04–0.28 | 3.39 | 2.24 | 0.924 |
3.3. Kinetics of adsorption
The kinetics of cadmium and lead ion adsorption onto the fabricated NCM were analyzed at various time intervals using the pseudo-first-order and pseudo-second-order kinetic models. The pseudo-first-order kinetic model is expressed as
(5) |
The pseudo-second-order kinetic model can be written as
(6) |
The rate constant of the pseudo-second-order kinetic model and qe,cal are estimated from the intercept and the slope of the linear plots of t∕qt versus time (min), respectively (see Figures 12a, b) [63]. Figures 12c, d indicate that with increasing initial concentration, the removal percentages of both metal ions decrease. The decrease in removal efficiency with increasing metal ion concentration may be due to the fact that with increasing metal ion concentration, more surface sites are increasingly covered, and therefore at higher metal ion concentrations, the adsorption capacity of the nanocomposite is lost. Hence, at low concentration, the proportions of initial metal concentration to available binding sites are greater, leading to higher uptake [64, 65]. As a result, lack of access to free binding sites reduces the overall removal efficiency [66]. Furthermore, it was observed that the adsorption rates of cadmium and lead on the nanocomposite were faster in the initial stages. However, the rates slowed down with the passage of time and remained almost constant after the adsorption process reached equilibrium. Overall, the trend is the same for both metal ions. That is, by increasing the contact time, there is an increase in removal percentage [22, 67].
Kinetic parameters for the adsorption of cadmium and lead ions onto the fabricated NCM at 298 K
Ions | C0 (mg⋅L−1) | qe,exp (mg⋅g−1) | Pseudo-first-order kinetic model | Pseudo-second-order kinetic model | ||||
---|---|---|---|---|---|---|---|---|
k1 (min−1) | qe,cal (mg⋅g−1) | R2 | k2 (g⋅mg−1⋅min−1) | qe,cal (mg⋅g−1) | R2 | |||
Cd2+ | 10 | 6.73 | 0.047 | 1.22 | 0.904 | 0.127 | 6.78 | 0.999 |
Pb2+ | 10 | 6.81 | 0.076 | 3.15 | 0.995 | 0.051 | 6.99 | 0.998 |
The results from kinetic studies are listed in Table 3. It is clear that the values of the regression coefficient are near unity for both metal ions (R2 > 0.99) and experimental and calculated values of qe are almost near each other. This indicates that the pseudo-second-order kinetic model fits the data well as compared to the pseudo-first-order kinetic model.
This suggests that the chemical adsorption of heavy metal ions onto the NCM is the rate-limiting step [68]. Furthermore, the importance of diffusion during the adsorption process was analyzed by the intraparticle diffusion model [69]. This model describes the movement of ions from a bulk solution to the solid phase. Plots of qt against t1∕2 are not linear, and the lines do not pass through the origin. This means that some other processes are also involved in the adsorption. Therefore, in our case, the adsorption processes of both metal ions may not be controlled by the intraparticle diffusion kinetic model.
3.4. Adsorption mechanism
The adsorption mechanism depends on several factors such as binding or interaction characteristics, surface functional groups of adsorbents, and the chemistry of solutions [70]. The FTIR spectra of Cd(II) and Pb(II) loaded on the NCM surface were studied to determine the possible functional groups involved in the adsorption of both metal ions. In FTIR spectra, the absorption peaks of the Fe–O bond are slightly shifted to lower wavenumbers, which indicates that the Fe–O bond is involved in metal adsorption. It is evident from the results that carboxyl groups on the surface of the fabricated NCM are involved in the adsorption process. Therefore, overall, the adsorption mechanism includes both electronic attraction and chemical adsorption.
4. Conclusions
Spinal magnetite NPs were successfully synthesized using the RS extract, which were then used to prepare a polymer-based NCM using a casting technique. The samples were successfully characterized by UV–visible, X-ray diffraction, Fourier-transform infrared, field emission scanning electron microscopy, energy-dispersive X-Ray spectrometry, BET, and vibrating sample magnetometry techniques. The fabricated NCM was applied to the removal of cadmium and lead metal ions from aqueous solutions. The present study showed that the fabricated NCM can remove toxic heavy metal ions from aqueous solutions with a high percentage of up to ∼95% at low concentrations. The adsorption process reached equilibrium within 60 min at room temperature. The maximum removal of Cd2+ and Pb2+ ions from aqueous solutions was achieved at pH values of 6 and 8, respectively. The isotherm studies of both cadmium and lead ions revealed that the adsorption process followed well the Langmuir isotherm model. The kinetics of adsorption of both metal ions were found to be the best fit to the pseudo-second-order kinetic model. The adsorption mechanism included both electronic attraction and chemical adsorption.